Fire Rated Barrier

W-FBR1 Wall Application 

Rating:

1 Hour ASTM E119 against active Fire

Listing:

UL 263, ASTM E119, NFPA 251, UBC 7.1, ANSI A2.1, ULC S101

Dimensions:

24.00” L x 14.00” W x 3.20” D

  • For installation in 2 x 4” structure.

  • Fit within 16” and 24” On Center truss.

  • A maximum of 2 standard 3C-12AWG “Romex” wires shall penetrate the enclosure as per FRPS written installation instructions.

  • Apply Firestop seal to fill voids and cavities around the power supply electrical knockouts.

  • Maximum 1 Fixture/100 square feet.

    (Make sure you meet the local building code.)


FRB1 & FRB2- 
Fire Rated for Ceiling

Listing:

UL 263, ASTM E119, NFPA251, UBC7.1, ANSI A2.1, ULC S101

Metallic enclosure used for all types of recessed Housings

• For installation in a 2 x 10” (FRB1) and 2 x 8” (FRB2).
• Fit within 16” and 24” On Center truss.
• A maximum of 2 standard 3C-12AWG “Romex” wires shall penetrate the enclosure
as per FRPS written installation instructions.
• Apply Firestop seal to fill voids and cavities around the power supply electrical

• Maximum 2 Fixtures/36 square feet.
• Minimum On Center 24” within same truss cavity. • Minimum On Center 36” for adjacent truss cavity.
(Make sure you meet the local building code.)