Bussman

250V One Time - Time Delay 10KA CDNC Fuses CRN Quick shop
250V One Time - Time Delay 10KA CDNC Fuses CRN
Bussman

250V One Time - Time Delay 10KA CDNC Fuses CRN

$5.00

10kA Minimum Interrupting Rating

CRN

View product
250V Time Delay 200KA ECNR Quick shop
250V Time Delay 200KA ECNR
Bussman

250V Time Delay 200KA ECNR

$5.00

Benefits: • True dual-element construction allows sizing of 125% FLA for motor backup protection. • Superior overload and cycling capabilities. • Current limiting provides component short-circuit protection. Applications: • Recommended for AC power distribution system mains, feeders, and branch circuits. • Protection of motors and motor branch circuits. • Protection of transformers and other inductive loads. • All general-purpose applications including lighting

ECNR - 250Vac ECNR - (1-60A, 110-200A) 125Vdc; (225-600A) 250Vdc ECSR - 600Vac ECSR - (1-30A, 70-600A) 300Vdc (35-60A) 250Vdc Amp Rating: 1 - 600A Interrupting Rating: 200kA RMS Symmetrical Amps Current Limiting: RK5 Fuse Agency Approvals: UL Listed for US and Canada, Class RK5, Guide JDDZ, File E162363 Interrupting Rating: ECNR/ECSR 20kA DC

View product
600V Time Delay 10KA CDSC Fuses CRS Quick shop
600V Time Delay 10KA CDSC Fuses CRS
Bussman

600V Time Delay 10KA CDSC Fuses CRS

$11.50

10kA Minimum Interrupting Rating

CRS

View product
600V Time Delay 200KA RK5 ECSR Quick shop
600V Time Delay 200KA RK5 ECSR
Bussman

600V Time Delay 200KA RK5 ECSR

$11.00

Benefits: • True dual-element construction allows sizing of 125% FLA for motor backup protection. • Superior overload and cycling capabilities. • Current limiting provides component short-circuit protection. Applications: • Recommended for AC power distribution system mains, feeders, and branch circuits. • Protection of motors and motor branch circuits. • Protection of transformers and other inductive loads. • All general-purpose applications including lighting

ECSR - (1-30A, 70-600A) 300Vdc (35-60A) 250Vdc Amp Rating: 1 - 600A Interrupting Rating: 200kA RMS Symmetrical Amps Current Limiting: RK5 Fuse Agency Approvals: UL Listed for US and Canada, Class RK5, Guide JDDZ, File E162363 Interrupting Rating: ECNR/ECSR 20kA DC

View product
Class L 200KA One Time LCU Quick shop
Class L 200KA One Time LCU
Bussman

Class L 200KA One Time LCU

$150.00

View product
Class L 200KA Time Delay LCL Fuses Quick shop
Class L 200KA Time Delay LCL Fuses
Bussman

Class L 200KA Time Delay LCL Fuses

$245.00

Eaton Edison LCL fuse, Non-indicating, 600V, 200 kAIC, Non Indicating, Bolt, Copper link fuses
View product
Quick shop
Bussman

EDCC & ATDR

$10.00

View product
Fuse Reducers Quick shop

Bussman

Fuse Reducers

from $21.00

Fuse Reducers
Bussman

Fuse Reducers

$21.00

Features: • Fuse reducers install on fuses and permit smaller size fuses to be used in larger amp size switches and blocks. • Reducers will fit into any panel or switch including the dead-front type. • Strong contact is maintained both mechanically and electrically. • UL Listed. • There are no reducers to go from 250V to 600V. • There are no reducers for switching from one fuse class to another. • There are no reducers for Class T or Class L fuses.
View product
J Time Delay 200KA 600V/250V AJT Quick shop
J Time Delay 200KA 600V/250V AJT
Bussman

J Time Delay 200KA 600V/250V AJT

$14.00

Price Per

AJT

Catalog Symbol: JDL Dual-Element, Time-Delay – 10 seconds (minimum) at 500% rated current Current-Limiting Volts: 600Vac (or less) Amps: 1 to 60A IR: 200kA RMS Sym. 300kA RMS Sym. (self certified) Agency Information: CE, UL Listed — Class J, Guide JDDZ, File E162363, CSA Certified, HRCI-J 200,000 AIR, Class J per CSA 22.2 No. 248.8, Class 1422-02, File 53787 Features • True dual-element fuses with a minimum 10 second time-delay at 500% overload. • Long time-delay minimizes needless fuse openings due to temporary overloads and transient surges. • Can often be sized for back-up protection against motor burnout from overload or single-phasing if other overload protective devices fail. • High interrupting rating to safely interrupt overcurrents up to 300kA (self certified). • High degree of current limitation due to the fast speed-of-response to short-circuits. • Faster response to damaging short-circuit currents than mechanical overcurrent protective devices.

View product
Type J One Time 200KA 600V/250V A4J Quick shop
Type J One Time 200KA 600V/250V A4J
Bussman

Type J One Time 200KA 600V/250V A4J

$12.00

A4J

Catalog Symbol: JFL Quick-Acting Current-Limiting Volts: 600Vac (or less) Amps: 1 to 60A IR: 200kA RMS Sym. Agency Information: CE, UL Listed, Std. 248-8, Class J, Guide JDDZ, File E162363, CSA Certified, HRCI-J C22.2 No. 248.8, Class 1422-02, File 53787 Features • Single-element, current-limiting fuses provide superior short-circuit protection. • Protects low interrupting capacity circuit breakers. Limits the short-circuit current to meet the interrupting capacity requirements of existing equipment. • On older systems available short-circuit current may exceed the interrupting capacity of the circuit breakers, fuses can be installed in series with existing equipment. • Well suited for lighting and heating circuits and other non-inductive loads. • Provides component short-circuit protection in compliance with NEC® 110-10, where protection devices shall clear a fault without “extensive damage” to the circuit components. • High interrupting rating helps meet the requirements of future system expansion and the increases in available utility short-circuit current. •

View product